The short version of quality control fits in a sentence. The long version — which is the one that helps — is below.
This page was last updated on 2025-10-10 and is reviewed periodically as new material appears.
High-performance liquid chromatography is an analytical technique that separates components in a liquid sample by passing them through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in how analytes partition between the mobile phase and the stationary phase cause them to exit the column at different times. Detection then records a signal proportional to the amount of each separated substance. The resulting chromatogram provides retention times and peak areas for identification and quantification.
Instrumentation includes a solvent delivery system, an autosampler, a column oven, and one or more detectors. Reversed-phase columns with chemically modified silica are widely used, but normal-phase, ion-exchange, size-exclusion, and affinity modes exist for specific separations. Detectors may rely on ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry. Column temperature, mobile phase composition, and flow rate are adjusted to improve resolution. System pressure is monitored because rising pressure can indicate column blockage or deteriorating packing.
Several separation modes exist, including reversed-phase, normal-phase, ion-exchange, size-exclusion, and hydrophilic interaction liquid chromatography. Reversed-phase uses a nonpolar stationary phase with a polar mobile phase and is widely applied to small organic molecules. Gradient elution changes mobile phase composition during the run, while isocratic elution keeps it constant. Column chemistry, particle size, temperature, flow rate, and mobile phase pH all influence retention and resolution. Method development selects conditions that separate analytes from matrix components and from each other.
Detection commonly uses ultraviolet-visible absorbance, fluorescence, refractive index, or mass spectrometry. Ultraviolet detection depends on molecular chromophores that absorb light at specific wavelengths. Mass spectrometry provides mass information and sensitive quantification, often after electrospray ionization. Before sample batches, performance checks examine resolution, elution time repeatability, peak symmetry, and plate count. Matrix effects and co-elution remain recognized uncertainties; formal validation studies and orthogonal detection help address them. Detector choice depends on analyte properties and required sensitivity.
High-performance liquid chromatography, or HPLC, separates dissolved compounds by passing a liquid mobile phase through a packed column. Components distribute differently between the stationary phase and the moving liquid, so they travel at different speeds and exit at different times. A detector records these eluting bands as peaks, and peak area or height relates to amount. The technique supports testing in pharmaceuticals, foods, environmental samples, and industrial chemicals. Quantification usually depends on calibration with known standards.
| Property | Value | Notes |
|---|---|---|
| Separation principle | Differential partitioning | Analytes distribute between mobile and stationary phases. |
| Mobile phase | Liquid solvent mixture | Composition controls retention and selectivity. |
| Stationary phase | Packed column particles | Often chemically bonded silica. |
| Typical detector | UV-Vis or photodiode array | Mass spectrometry is also common. |
| Common synonym | High-performance liquid chromatography | Abbreviated as HPLC. |
High-performance liquid chromatography testing separates components of a liquid sample by forcing a mobile phase through a packed column. The stationary phase inside the column interacts with analytes to different degrees, so each compound exits at a characteristic retention time. A pump delivers solvent at controlled flow and pressure, while an injector introduces a precise sample volume. Detectors such as ultraviolet-visible, fluorescence, refractive index, or mass spectrometric instruments record the separated bands. The resulting chromatogram provides qualitative and quantitative information about the mixture.
Separation modes differ by the chemistry of the stationary phase and the composition of the mobile phase. Reversed-phase testing uses a nonpolar column and polar solvents, making it common for pharmaceutical, environmental, and food analytes. Normal-phase testing uses a polar column and nonpolar solvents for compounds that are poorly retained in reversed-phase systems. Ion-exchange and ion-pair methods separate charged species, while size-exclusion methods sort molecules by hydrodynamic volume. Gradient elution changes solvent strength over time to resolve complex mixtures, and isocratic elution holds solvent composition constant for simpler assays.
Key performance measures include retention time, peak area, peak height, resolution, tailing factor, and plate count. Retention time helps identify a peak under fixed conditions, but confirmation often requires a second method or detector. Peak area and height relate to concentration through calibration curves, which may be linear or nonlinear depending on the detector response. Resolution describes separation between adjacent peaks, while tailing factor and plate count describe peak shape and column efficiency. Performance checks verify these values before and during a run to confirm that the instrument is performing within limits.
Method validation demonstrates that an analytical procedure is suitable for its intended purpose. Typical validation characteristics include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Regulatory guidance from bodies such as the International Council for Harmonisation and the United States Pharmacopeia outlines expectations, though specific criteria depend on the product and method. System suitability tests are run before sample analysis to confirm resolution, peak symmetry, column efficiency, and injection repeatability. Failure of these checks can invalidate a batch of measurements.
Practical HPLC testing depends on careful sample preparation and instrument maintenance. Samples may require filtration, dilution, pH adjustment, or extraction to avoid column damage and matrix interference. Mobile phases are degassed and filtered, and columns are equilibrated before injection. Common problems include peak tailing, baseline drift, ghost peaks, carryover, and co-elution of analytes. Documentation of instrument logs, calibration records, and electronic audit trails supports data integrity and traceability. Ongoing training and routine maintenance help reduce variability between analysts and laboratories.
Quality control laboratories use HPLC to check identity, purity, concentration, and stability of raw materials and finished products. A validated method specifies the column, mobile phase, flow rate, detection wavelength, injection volume, and run time. Samples are prepared and compared against reference standards of known concentration. The resulting chromatogram provides quantitative data, such as assay values and impurity levels. This approach is common in pharmaceutical, food, environmental, and industrial testing where consistent measurements are required.
Method validation establishes that an HPLC procedure is suitable for its intended use. Key parameters include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Accuracy measures agreement with a true or accepted value, while precision describes repeatability and intermediate precision. Specificity confirms that the method measures the analyte without interference from impurities, degradants, or excipients. Validation is documented in a protocol and report, and acceptance criteria are set before experiments begin. Regulatory guidance varies by region, but the general principles are widely harmonized.
System suitability testing is performed before and during analytical runs to confirm that the instrument and method are working as expected. Common checks include retention time, peak area, resolution between critical pairs, tailing factor, and theoretical plate count. Results are compared with predefined limits, and a failed check requires investigation before sample results are reported. Quality control samples at low, middle, and high concentrations are injected at intervals to monitor accuracy and precision. Blank injections detect carryover and contamination, while control charts track performance over time.
Data handling and documentation are central to HPLC quality control. Electronic systems should have audit trails that record changes to methods, sequences, and results. Integration parameters, such as peak baseline and threshold, can affect reported areas and must be defined in advance. Out-of-specification results trigger a structured investigation that may include reanalysis, instrument checks, and review of sample preparation. Regulatory inspections often examine raw data, audit trails, and training records to verify that reported results are traceable and reliable.
Method validation examines whether an HPLC procedure is suitable for its intended purpose. Common parameters include accuracy, precision, specificity, linearity, range, detection limit, quantification limit, and robustness. Accuracy describes closeness to a true or accepted value, while precision describes agreement among repeated measurements. Specificity shows whether the method can measure the analyte without interference from related substances. Robustness tests small deliberate changes in flow, temperature, or solvent composition. Validation is not a one-time event; methods may need partial revalidation after changes to instruments, columns, sample handling, or specification limits. Regulatory guidance provides frameworks, but some details remain method-specific.
Regulatory and pharmacopeial texts shape how HPLC testing is performed and documented. The International Council for Harmonisation provides validation guidance, while pharmacopeias publish general chromatography chapters and monographs for specific materials. Accreditation standards such as ISO/IEC 17025 address laboratory competence and traceability. Inspectors may review instrument qualification, analyst training, reference material control, and electronic records. Open questions include how best to validate methods for new complex products and how to handle automated data processing. Laboratories generally resolve these issues through risk assessment, method lifecycle management, and documented scientific justification.
In quality control laboratories, HPLC testing supports batch release, raw material checks, stability studies, and impurity profiling. A validated method defines sample preparation, instrument settings, calibration, and acceptance criteria. Analysts compare results with specifications and investigate out-of-specification outcomes before a batch is approved. Documentation includes chromatograms, integration records, audit trails, and reagent details. Because results influence product decisions, laboratories follow formal quality systems and data integrity rules. The exact tests and limits depend on the material, its intended use, and the applicable regulatory framework.
The Affordable Insulin Now Act is a bill in the United States Congress intended to cap out-of-pocket insulin prices under private health insurance and Medicare at no more than $35 per month. The bill was first introduced on February 25, 2022, by Representative Angie Craig (D-MN). On March 31, 2022, the bill passed the House of Representatives, 232–193. A version of the bill contained in the Inflation Reduction Act (IRA) for private health insurance was blocked by Senate Republicans on August 8, 2022. However, the inflation reduction legislation did cap out-of-pocket insulin cost at $35 per monthly prescription for the following: Medicare Part D enrollees, which was legislated at effective on January 1, 2023. Medicare Part B enrollees, which was effective starting on July 1, 2023.
If analytes are too small to generate a readable signal for determining concentration, the assay matrix can be modified. CD/DVD based assays utilize the optical properties of gold. Gold nanoparticle bioconjugates are tracers used to increase the sensitivity of the assay. The gold nanoparticles can be identified with photometric or plasmonic detectors. The smaller the nanoparticles are, the more sensitive the assay becomes. Silver enhancer solution is also used to increase the reflective properties of samples. Gold nanoparticles have catalytic properties which cause them to reduce silver ions to silver metal. The silver metal deposits on the analytes and causes signals to be amplified. Silver metal is more easily detectable by cameras, scanners, or other drives than is the analyte alone. Still, this enhancement procedure requires many additional reaction and washing steps which could lead to analytical errors.
12(S)-HpETE and 12(S)-HETE induce itching responses when injected into the skin of mice; this has led to the suggestion that these metabolites contribute to the itching (i.e. clinical pruritus) which accompanies such conditions as atopic dermatitis, contact dermatitis, urticaria, chronic renal failure, and cholestasis. Since it mediates 12(S)-HETE-induced itching in the mouse model, BLT2 rather than GPR31 may mediate human itch in these reactions.
== In nuclear power reactors == In any operating nuclear reactor containing 238U, some plutonium-239 will accumulate in the nuclear fuel. Unlike reactors used to produce weapons-grade plutonium, commercial nuclear power reactors typically operate at a high burnup that allows a significant amount of plutonium to build up in irradiated reactor fuel. Plutonium-239 will be present both in the reactor core during operation and in spent nuclear fuel that has been removed from the reactor at the end of the fuel assembly's service life (typically several years). Spent nuclear fuel commonly contains about 0.8% plutonium-239. Plutonium-239 present in reactor fuel can absorb neutrons and fission just as uranium-235 can. Since plutonium-239 is constantly being created in the reactor core during operation, the use of plutonium-239 as nuclear fuel in power plants can occur without reprocessing of spent fuel; the plutonium-239 is fissioned in the same fuel rods in which it is produced. Fissioning of plutonium-239 provides more than one-third of the total energy produced in a typical commercial nuclear power plant. Reactor fuel would accumulate much more than 0.8% plutonium-239 during its service life if some plutonium-239 were not constantly being "burned off" by fissioning. A small percentage of plutonium-239 can be deliberately added to fresh nuclear fuel. Such fuel is called MOX (mixed oxide) fuel, as it contains a mixture of uranium dioxide (UO2) and plutonium dioxide (PuO2). The addition of plutonium-239 reduces the need to enrich the uranium in the fuel.
Sources: en.wikipedia.org
=== Beauty supplements === Beauty supplements, particularly those aimed at improving the health of skin, hair, and nails, are commonly marketed within the wellness and supplement markets. These products typically include ingredients, such as collagen, which is reputed to improve the appearance and condition of skin, hair, and nails. Other typical ingredients include biotin, keratin, and omega-3 fatty acids, which are promoted for their alleged benefits to skin and hair health. Demand for these beauty supplements has risen markedly in the 21st century. Despite the apparent rise in demand, scientific evidence supporting the efficacy of ingredients like biotin for the purpose of hair growth remains unproven.
=== Polyaspartic acid === Polyaspartic acid, like IDS, binds to calcium and other heavy metal ions. It has many practical applications including corrosion inhibitors, wastewater additives, and agricultural polymers. A polyaspartic acid-based laundry detergent was the first laundry detergent in the world to receive the EU flower ecolabel. Calcium binding ability of polyaspartic acid has been exploited for targeting of drug-loaded nanocarriers to bone. Preparation of hydrogels based on polyaspartic acid, in a variety of physical forms ranging from fiber to particle, can potentially enable facile separation of the chelated ions from a solution. Therefore, despite being weaker than EDTA, polyaspartic acid can still be regarded as a viable alternative due to these features as well as biocompatibility and biodegradability.
=== Hormonal === Vitamin D metabolism is regulated not only by the negative feedback mechanism of calcitriol but also by two hormones: parathyroid hormone (PTH) and fibroblast growth factor-23 (FGF-23). These hormones are essential for maintaining the body's calcium and phosphate balance. Parathyroid hormone (PTH) regulates serum calcium through its effects on bone, kidneys, and the small intestine.Bone remodeling, a constant process throughout life, involves bone mineral content being released by osteoclasts (bone resorption) and deposited by osteoblasts. PTH enhances the release of calcium from the large reservoir contained in the bones. It accomplishes this by binding to osteoblasts, in this way inhibiting the cells responsible for adding mineral content to bones, thus favoring the actions of osteoclasts. In the kidneys, around 250 mmol of calcium ions are filtered into the glomerular filtrate per day, with the great majority reabsorbed and the remainder excreted in the urine. PTH inhibits reabsorption of phosphate (HPO42−) by the kidneys, resulting in a decrease in plasma phosphate concentration. Given that phosphate ions form water-insoluble salts with calcium, a decrease in the phosphate concentration in plasma (for a given total calcium concentration) increases the amount of ionized (free) calcium. A third important effect of PTH on the kidneys is stimulation of the conversion of 25-hydroxy vitamin D into 1,25-dihydroxy vitamin D (calcitriol). This form of vitamin D is the active hormone which promotes calcium uptake from the intestine via the action of calbindin.
Sources: en.wikipedia.org
== Honors and awards == In December 2010 he was acknowledged in his individual capacity, as the "Cold Chain Personality of the Year" by an expert panel hosted by KPMG-Supply Chain Leadership Council. The award was in appreciation for individual contributions to the industry and for aligning focus on the socio-economic fabric in India. In 2012 he was applauded with the "Exemplary Thought Leadership Award" by the ICE Centre of Excellence in India. In 2014 he won the prestigious Agribusiness Leadership Award at the annual Agriculture Leadership Summit in New Delhi. In 2016, ISHRAE lauded him as honorary lifetime member, their first ever. He is expert member of the Empowered Committee in the Ministry of New & Renewable Energy for implementation of Montreal Protocol and on the Global Advisory Committee of the International Solar Alliance (ISA) In India, he is recognised as one among the few eminent persons from the private sector who have shifted over to public service by taking on specialist advisory roles in government. His authored documents are frequently cited in the cold chain domain. He is recipient of various recognition and achievement awards from the cold chain industry in India.
=== Infrared ear thermometers === Diatek Corporation and NASA developed an aural thermometer that measures the thermal radiation emitted by the eardrum, similar to the way the temperature of stars and planets are measured. This method avoids contact with mucous membranes and permits rapid temperature measurement of newborn or incapacitated patients. NASA supported the Diatek Corporation through the Technology Affiliates Program.
Tulips are called lale in Turkish (from the Persian: لاله, romanized: laleh from لال lal 'red'). When written in Arabic letters, lale has the same letters as Allah, which is why the flower became a holy symbol. It was also associated with the House of Osman, resulting in tulips being widely used in decorative motifs on tiles, mosques, fabrics, crockery, etc. in the Ottoman Empire. The tulip was seen as a symbol of abundance and indulgence. The era during which the Ottoman Empire was wealthiest is often called the Tulip era or Lale Devri in Turkish. Tulips became popular garden plants in the east and west, but, whereas the tulip in Turkish culture was a symbol of paradise on earth and had almost a divine status, in the Netherlands it represented the briefness of life. By contrast to other flowers such as the coneflower or lotus flower, tulips have historically been capable of genetically reinventing themselves to suit changes in aesthetic values. In his 1597 herbal, John Gerard says of the tulip that "nature seems to play more with this flower than with any other that I do know". When in the Netherlands, beauty was defined by marbled swirls of vivid contrasting colours, the petals of tulips were able to become "feathered" and "flamed". However, in the 19th century, when the English desired tulips for carpet bedding and massing, the tulips were able to once again accommodate this by evolving into "paint-filled boxes with the brightest, fattest dabs of pure pigment".
Furthermore, in the 1951 film Προ παντός ψυχραιμία (Pro pantós psykhaimía, Above all, stay calm) starring Mimis Fotopoulos and Dinos Iliopoulos, Iliopoulos makes a direct reference to frappé coffee, which the two protagonists prepared with a shaker at Pavlidis Patisserie on Amerikis Square in Athens: "If we make even the slightest mistake, they’ll turn us into a frappé!". Vakondios' improvised experiment is thought to have established the frappé which quickly grew in popularity in Greece. Nestlé capitalized on the drink with intense marketing campaigns in the 1980s that broadened the drink's popularity and left the brand name Nescafé inextricably linked with the frappé. Today, the drink is usually simply called a 'frappé' in Greece, but in the past, it was often called a 'Nescafé frappé'.
Sources: en.wikipedia.org
HPLC separates and detects individual compounds in a liquid sample, producing peaks at characteristic retention times. Peak area or height can be used to estimate concentration when calibrated with known standards. It does not identify unknown compounds with certainty unless additional detectors or reference materials are used.
Pressure drives the liquid mobile phase through a column packed with small particles. Without pressure, flow would be very slow or stop because the packed bed resists liquid movement. Modern pumps maintain a steady flow despite the resistance.
A chromatogram is a plot of detector signal against time after sample injection. Each peak represents a compound or group of compounds eluting from the column. Retention time and peak area are the main measurements read from the plot.
HPLC separates and quantifies compounds in a liquid sample. Detectors produce a response proportional to the amount of a compound passing through the flow cell. Identification by retention time requires comparison with a known standard.