If you have been reading about precision and want a single page that covers the useful parts, this is it: definitions, context, how it is studied, and the questions that come up repeatedly.
Updated 2025-09-18. Numbers and descriptions here follow the published literature rather than marketing material.
Routine HPLC testing compares a sample result with a calibration curve prepared from known reference standards. Peak area or peak height is plotted against concentration, and the curve is used to estimate unknown amounts. Retention time supports tentative identification when compared with a standard, though mass spectrometry or another confirmatory method may be needed for definitive identification. Pre-run checks verify repeatability, resolution, and peak symmetry before sample analysis. Limits of detection and quantification describe the smallest amounts that can be reliably observed or measured. Sample preparation, filtration, and degassing help prevent column damage and inconsistent results.
High-performance liquid chromatography is an analytical technique that separates components in a liquid sample. A pump moves a liquid mobile phase through a column packed with a solid stationary phase. Compounds interact differently with both phases and travel at different rates, leaving the column at distinct retention times. A detector records these arrivals as peaks on a chromatogram. The resulting pattern supports identification and quantification of substances in mixtures. Modern instruments use high pressure to force solvent through small particles, which improves speed and resolution compared with older low-pressure liquid chromatography methods.
Separation in HPLC depends on the chemistry of the stationary phase, the composition of the mobile phase, and the physical properties of the column. Reverse-phase separations use a nonpolar stationary phase and a polar mobile phase, and they are common for many organic compounds. Ion-exchange, size-exclusion, and normal-phase modes serve other classes of analytes. Gradient elution changes solvent strength over time, while isocratic elution holds it constant. Flow rate, temperature, particle size, and column length all influence peak shape and resolution. Detection may use ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry, depending on the analyte and the required sensitivity.
Instrumentation includes a solvent delivery system, an autosampler, a column oven, and one or more detectors. Reversed-phase columns with chemically modified silica are widely used, but normal-phase, ion-exchange, size-exclusion, and affinity modes exist for specific separations. Detectors may rely on ultraviolet absorbance, fluorescence, refractive index, or mass spectrometry. Column temperature, mobile phase composition, and flow rate are adjusted to improve resolution. System pressure is monitored because rising pressure can indicate column blockage or deteriorating packing.
Separation performance depends on particle size, pore size, column length, and the chemistry of the stationary phase. Smaller particles generally improve efficiency but require higher pressure and suitable instrumentation. The mobile phase often contains buffers and organic solvents that influence retention and selectivity. Testing labs select conditions based on the analytes, sample matrix, and required sensitivity. Method development frequently involves screening several columns and solvent mixtures before a final set of conditions is chosen.
High-performance liquid chromatography is an analytical technique that separates components in a liquid sample by passing them through a packed column under pressure. A pump delivers a mobile phase at a controlled flow rate, and an injector introduces the sample into the stream. Differences in how analytes partition between the mobile phase and the stationary phase cause them to exit the column at different times. Detection then records a signal proportional to the amount of each separated substance. The resulting chromatogram provides retention times and peak areas for identification and quantification.
| Property | Value | Notes |
|---|---|---|
| Common abbreviation | HPLC | High-performance liquid chromatography |
| Separation basis | Differential partitioning | Between liquid mobile phase and solid stationary phase |
| Common mode | Reverse phase | Nonpolar column, polar mobile phase |
| Typical detector | UV-Vis absorbance | Widely used for compounds with chromophores |
| Typical column particle size | 2–5 µm | Smaller particles can improve resolution |
Quality control laboratories use HPLC to check identity, purity, concentration, and stability of raw materials and finished products. A validated method specifies the column, mobile phase, flow rate, detection wavelength, injection volume, and run time. Samples are prepared and compared against reference standards of known concentration. The resulting chromatogram provides quantitative data, such as assay values and impurity levels. This approach is common in pharmaceutical, food, environmental, and industrial testing where consistent measurements are required.
Method validation demonstrates that an analytical procedure is suitable for its intended purpose. Typical validation characteristics include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Regulatory guidance from bodies such as the International Council for Harmonisation and the United States Pharmacopeia outlines expectations, though specific criteria depend on the product and method. System suitability tests are run before sample analysis to confirm resolution, peak symmetry, column efficiency, and injection repeatability. Failure of these checks can invalidate a batch of measurements.
Validation demonstrates that a method is suitable for its intended use. Typical performance characteristics include accuracy, precision, specificity, linearity, range, limit of detection, limit of quantitation, and robustness. Regulators and standards organizations provide frameworks, but specific requirements depend on the application and jurisdiction. System suitability tests are run before sample analysis to confirm resolution, peak symmetry, retention time repeatability, and sensitivity. A validated method is not permanently fixed; changes may require partial or full revalidation.
Routine HPLC testing depends on controlled reagents, calibrated instruments, and documented procedures. Columns degrade over time, so retention times and peak shapes are monitored for drift. Mobile phases are filtered and degassed to prevent pump damage and detector noise. Reference standards must be traceable and stored under suitable conditions. Data handling systems record injections, calculations, and audit trails. Quality control samples interspersed with unknowns help detect errors during a run.
Developing an HPLC method begins with defining the purpose, such as quantifying a main component, measuring impurities, or confirming identity. Analysts select separation mode, column, mobile phase, detection, and sample preparation based on analyte properties and matrix. Experiments vary solvent strength, pH, buffer type, and temperature to achieve resolution between critical peaks. The goal is a robust method that produces reliable results across instruments and operators. Method development often involves trial runs and statistical optimization.
Quality control for HPLC testing combines scheduled checks, documented procedures, and review of results. Before sample analysis, system suitability testing confirms that the instrument, column, and method meet predefined criteria. Common criteria include resolution between critical peaks, retention time precision, peak tailing, and theoretical plate count. Failure triggers investigation before results are reported. Records link raw data, calculations, instrument logs, and analyst identity to each batch, supporting audits and repeat analysis.
Method validation evaluates accuracy, precision, specificity, linearity, range, detection limit, quantitation limit, and robustness. Regulatory guidance for pharmaceuticals, foods, and environmental testing defines expected documentation and acceptance criteria. Verification confirms that a validated method works in a specific laboratory with its own instruments and reagents. Calibration curves use reference standards with known purity and traceability, while measurement uncertainty is estimated from validation data, control charts, and collaborative studies. The scope of validation depends on the method's intended use.
Routine quality control monitors retention time shifts, baseline noise, system pressure, and peak shape. Trends can reveal column aging, mobile phase preparation errors, detector drift, or sample degradation. Corrective actions may include replacing the column, preparing fresh mobile phase, or recalibrating the detector. Stability testing often uses HPLC to measure parent compound loss and degradation product formation. Open questions remain about how accelerated stability results extrapolate to long-term storage under varied conditions.
=== Apodization in mass spectrometry === During oscillation within an Orbitrap, a transient signal may not be stable until the ions settle into their oscillations. Toward the end, subtle ion collisions add up to cause noticeable dephasing. This presents a problem for the Fourier transform, as it averages the oscillatory signal across the length of the time-domain measurement. Software allows "apodization", the removal of the front and back section of the transient signal from consideration in the FT calculation. Thus, apodization improves the resolution of the resulting mass spectrum. Another way to improve the quality of the transient is to wait to collect data until ions have settled into stable oscillatory motion within the trap.
Market Place (formerly Market Place by Jasons, Jason's Food & Living, and Jasons ichiba) in Hong Kong is a high-end supermarket chain owned by DFI Retail Group. The chain also has a joint venture in mainland China with Beijing Hualian Group called BHG Market Place and formerly ran stores (Jasons Market Place) in Taiwan until they were sold to Carrefour. The Malaysian chain called Mercató (formerly Jasons Food Hall) is owned by Macrovalue Sdn Bhd. after its acquisition of DFI Malaysian food retailing business in 2023. Cold Storage Fresh (formerly Market Place, Jasons, and Jasons Deli) in Singapore is also owned by Macrovalue Sdn Bhd since 2025. The Marketplace (formerly Market Place by Rustan's) in the Philippines has been owned by Robinsons Retail Holdings since 2018, before which it was owned by Rustan Supercenters. DFI also operates further similar supermarkets under the 3hreeSixty and Oliver's The Delicatessen brands in Hong Kong and other supermarkets around Asia with Wellcome.
=== Acquisition and merging of Novartis' vaccine business === In October 2014, Novartis announced its intention to sell its influenza vaccine business, including its development pipeline, to CSL for $275 million. CSL merged it into its BioCSL operation. In November 2015, BioCSL rebranded the combined business with Novartis Influenza Vaccines as Seqirus [Sek-eer-us], creating the world's second-largest influenza vaccine company. In August 2017, the business announced it would acquire Calimmune and its stem cell therapy platform. Completed in 2018, Seqirus's plant in Holly Spring, NC was funded with $59 million from the U.S. government. in June 2020, CSL announced it would exercise its right to acquire Vitaeris. In December 2021, the business announced it would acquire Swiss drugmaker, Vifor Pharma AG, for $11.7 billion. In August 2022, CSL rebranded all of its divisions to start with the CSL name. Therefore, the divisions became CSL Behring, CSL Plasma, CSL Seqirus, and CSL Vifor.
Despite claims by numerous anthropologists and ethnologists, such as Plutarco Naranjo, regarding the millennial usage of ayahuasca, compelling evidence substantiating its pre-Columbian consumption is yet to be firmly established. As articulated by Dennis McKenna: "No one can say for certain where the practice may have originated, and about all that can be stated with certainty is that it was already spread among numerous indigenous tribes throughout the Amazon Basin by the time Ayahuasca came to the attention of Western ethnographers in the mid-nineteenth century" The first western references of the ayahuasca beverage dates back to seventeenth century, during the European colonization of the Americas. The earlier report is a letter from Vincente de Valverde to the Holy Office of the Inquisition. Jose Chantre y Herrera still in the seventeenth century, provided the first detailed description of a "devilish potion" cooked from bitter herbs and lianas (called ayaguasca) and its rituals: "[...] In other nations, they set aside an entire night for divination. For this purpose, they select the most capable house in the vicinity because many people are expected to attend the event. The diviner hangs his bed in the middle and places an infernal potion, known as ayahuasca, by his side, which is particularly effective at altering one's senses. They prepare a brew from bitter vines or herbs, which, when boiled sufficiently, must become quite potent. Since it's so strong at altering one's judgment in small quantities, the precaution is not excessive, and it fits into two small pots.
Sources: en.wikipedia.org
ArH + CH2O → ArCH2OH When conducted in the presence of hydrogen chloride, the product is the chloromethyl compound, as described in the Blanc chloromethylation. If the arene is electron-rich, as in phenols, elaborate condensations ensue. With 4-substituted phenols one obtains calixarenes. Phenol results in polymers.
==== Appeal ==== In March 1996 Rose announced her intention to appeal against her sentence, contending that extensive press coverage had rendered witness testimony unreliable, that no physical evidence existed to attest she had participated in any of the murders, that the final instructions delivered by the judge to the jury had been biased in favour of the prosecution, and that undue weight had been given to the similar fact evidence introduced at her trial. This appeal was rejected by the Lord Chief Justice, Lord Taylor of Gosforth, who contended Rose had received a fair trial and efficient legal representation. In July 1997 then-Home Secretary Jack Straw subjected Rose to a whole life tariff, effectively denying her any possibility of parole. In October 2000, Rose again announced that she would appeal against her sentence via her solicitor, Leo Goatley. In September 2001 she announced her intention to abandon her appeals, stating she would never feel free even if released. She maintains her innocence in any of the murders.
They are cigar-shaped but slightly broader at the "front" end, which is the aboral, vegetal-pole end and eventually attaches to a substrate if the species has a polyp stage. Anthozoan larvae either have large yolks or are capable of feeding on plankton, and some already have endosymbiotic algae that help to feed them. Since the parents are immobile, these feeding capabilities extend the larvae's range and avoid overcrowding of sites. Scyphozoan and hydrozoan larvae have little yolk and most lack endosymbiotic algae, and therefore have to settle quickly and metamorphose into polyps. Instead, these species rely on their medusae to extend their ranges.
Sources: en.wikipedia.org
The GRP RNA motif is a conserved RNA structural element identified in introns of glycine-rich RNA-binding protein genes, including GRP7 and GRP8. It is associated with alternative splicing and nonsense-mediated decay (NMD). GRP RNA motif has been reported as a cis-regulatory element, that modulates binding of GRP7 and GRP8 proteins to their RNA targets. The motif is predicted to form a stem-loop structure of approximately 20 base pairs. An alternative 5′ splice site is located near the base of the stem, suggesting that RNA structure may influence splice-site accessibility. In Arabidopsis thaliana (At), AtGRP7 and AtGRP8 are circadian clock-regulated RNA-binding proteins that form an interlocked auto-regulatory and cross-regulatory feedback network based on alternative splicing and NMD of their own pre-mRNAs, contributing to circadian output regulation, were transcript levels oscillate with a daily rhythm. GRP7 and GRP8 are also involved in regulating flowering time. Homologous motifs of GRP RNA motif have been identified in multiple plant species within the Pentapetalae clade.
== External links == "Cesium, Radioactive". NLM Hazardous Substances Databank. Archived from the original on 29 March 2016. Theodore Liolios. "Cesium-137 dirty bombs" (PDF). Archived from the original (PDF) on 21 July 2011.
is the heat flux vector. Because it expresses conservation of total energy, this is sometimes referred to as the energy balance equation of continuous media. The first law is used to derive the non-conservation form of the Navier–Stokes equations.
Mode I – Opening mode (a tensile stress normal to the plane of the crack), Mode II – Sliding mode (a shear stress acting parallel to the plane of the crack and perpendicular to the crack front), and Mode III – Tearing mode (a shear stress acting parallel to the plane of the crack and parallel to the crack front). When the size of the plastic zone at the crack tip is too large, elastic-plastic fracture mechanics can be used with parameters such as the J-integral or the crack tip opening displacement. The characterising parameter describes the state of the crack tip which can then be related to experimental conditions to ensure similitude. Crack growth occurs when the parameters typically exceed certain critical values. Corrosion may cause a crack to slowly grow when the stress corrosion stress intensity threshold is exceeded. Similarly, small flaws may result in crack growth when subjected to cyclic loading. Known as fatigue, it was found that for long cracks, the rate of growth is largely governed by the range of the stress intensity
Sources: en.wikipedia.org
HPLC testing measures the presence and amount of one or more compounds in a liquid sample. It separates mixture components and records detector responses as peaks, which are compared with reference standards. Results are usually reported as concentrations or relative percentages.
Retention time is the interval between sample injection and the detector response for a given compound. It depends on the compound's interactions with the stationary and mobile phases under set conditions. Matching a retention time to a standard supports tentative identification but is not always unique.
HPLC alone can separate unknown compounds and provide retention times, but it often cannot identify them with certainty. Coupling HPLC to mass spectrometry gives mass information that improves identification. Confirmation usually requires comparison with reference standards or complementary techniques.
HPLC separates and detects individual compounds in a liquid sample, producing peaks at characteristic retention times. Peak area or height can be used to estimate concentration when calibrated with known standards. It does not identify unknown compounds with certainty unless additional detectors or reference materials are used.